IMC Networks iMcV-LIM Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Převaděče síťových médií IMC Networks iMcV-LIM. IMC Networks iMcV-LIM Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
iMcV-LIM
Operation Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Operation Manual

iMcV-LIM Operation Manual

Strany 2 - Warranty

7 Link Fault Pass-Through (LFPT) Link Fault Pass-Through (LFPT) is a troubleshooting feature that combines TX and FX LinkLoss from both the local and

Strany 3

8 FiberAlert and Far End Fault Modules ship from the factory with troubleshooting features disabled. Refer to the help file to enable/disable this fe

Strany 4

9 FEF versus FA FEF is preferred when the devices at both ends of the fiber can interpret the FEF signal. This allows FEF to be turned on at both end

Strany 5

10 Auto Negotiation on iMcV-LIM iMcV-LIM modules include the feature Auto Negotiation. When Auto Negotiation is enabled, the module negotiates as a 1

Strany 6

11 LED Operation Each iMcV-LIM module features diagnostic LEDs that provide information on features and ports. FEF Glows green when a fiber end fault

Strany 7

12 Installation Troubleshooting • During installation, first test the fiber and twisted pair connections with all troubleshooting features disabled, t

Strany 8

13 Specifications Environmental Operating Temperature +32°F to +122°F (0°C to +50°C) Storage Temperature -13°F to +158°F (-25°C to +70°C) Humidity: 5

Strany 9

14 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, whi

Strany 10

15 Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing

Strany 11 - WARNING

16 Certifications CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC). European

Strany 12 - FEF versus FA

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursu

Strany 13

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2010 IMC Networks. All rig

Strany 14 - CONFIG CONTROL

iii Table of Contents FCC Radio Frequency Interference Statement ...ii Warranty...

Strany 15

1 About the iMcV-LIM The iMcV-LIM is a Fast Ethernet module which provides a single conversion between 100Base-TX twisted pair and 100Base-FX/SX singl

Strany 16

2 Managed Modules To manage one or more iMcV-LIM(s), an SNMP agent must be present in the chassis. To configure Managed Modules, install the module fi

Strany 17

3 - If another type of module is installed into the same slot in a chassis, the iMcV-LIM clears the memory of the previous configuration for that slot

Strany 18

4 iMcV-LIM DIP Switch on S1 Feature Default Setting 1 Auto Negotiation (AN) ON 2 Far End Fault (FEF) OFF 3 FX LinkLoss (FXLL) OFF 4 TX LinkLoss

Strany 19 - Laser de Classe 1

5 iMcV-LIM with SFP and Configuration Control DIP Switch on S1 Feature Default Setting 1 Auto Negotiation (AN) ON 2 Far End Fault (FEF) OFF 3 FX L

Strany 20

6 FX LinkLoss, TX LinkLoss, Link Fault Pass-Through, Far End Fault and FiberAlert iMcV-LIM modules include the troubleshooting features FiberAlert, TX

Komentáře k této Příručce

Žádné komentáře