iMcV-Giga-FiberLinX-II
Operation Manual
Above illustrations are representative; some minor differences may be present in actual product
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - Operation Manual

iMcV-Giga-FiberLinX-II Operation Manual Above illustrations are representative; some minor differences may be present in actual product

Strany 2 - Warranty

7 TX/SFP LEDs LNK/ACT: • Glows green when link is established on port. • Blinks green during data activity on port. FDX: • Glows yellow when port i

Strany 3

8 SFP/SFP LEDs LNK/ACT: • Glows green when link is established on port. • Blinks green during data activity on port. FDX: • Glows yellow when port i

Strany 4

9 Hardware Configuration Before installing the module in a chassis, there are two features that must be selected using the DIP switches. These selec

Strany 5

10 queried by SNMP. As a Remote unit, the iMcV-Giga-FiberLinX-II will respond to requests for management information from an attached Host unit. The

Strany 6

11 Software Configuration The following sections describe the features that can be configured. Refer to the iView² online help for iMcV-Giga-FiberLi

Strany 7

12 Bandwidth Control The iMcV-Giga-FiberLinX-II includes bi-directional bandwidth control in 32 Kbps increments (configurable via iView2). This allo

Strany 8

13 FX/TX LinkLoss and FiberAlert During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When an iMcV

Strany 9

14 will cause them to lock up when a fault occurs on the fiber. Only enable FiberAlert on the remote module. Link Fault Pass Through (LFPT) Link Fau

Strany 10

15 Loopback Testing The following functions are available during loopback testing. During loopback testing, management traffic entering the uplink

Strany 11

16 Host: No Learning on OPTICS and DATA Ports The Loopback feature can be set to disable address learning on the OPTICS (or UPLINK) and DATA ports,

Strany 12

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device, pursu

Strany 13

17 Using Telnet It is necessary to assign the iMcV-Giga-FiberLinX-II an IP address before using a Telnet session (this is not necessary when using UM

Strany 14

18 Basic Device Configuration After running through an initial self test, the screen will display the following message: Press <Enter> for Devi

Strany 15

19 NOTE It is necessary to reboot the iMcV-Giga-FiberLinX-II after making any modifications to the Saved Values for the changes to take effect. To r

Strany 16

20 This function enables all of the device traps. Use iConfig to configure the device to selectively activate and de-activate traps. Supported traps

Strany 17

21 Reboot Device By typing Reboot, the device will restart, which will result in a temporary loss of operation of the unit while it re-initializes. E

Strany 18

22 Clean Database—cleandb There are two levels of cleandb: The first level resets the Telnet/iConfig password and all of the SNMP database values. T

Strany 19

23 In the Port Status Values area of this screen it is possible to view the link status, link lost counter, duplex status, and port speed. In the Po

Strany 20

24 Advertise FlowC and Force FlowCtrl—the following are Advertise Control features. When using Flow Control functionality on any port, enable Flow Co

Strany 21

25 Transparent Mode The Transparent Mode screen is displayed when the iMcV-Giga-FiberLinX-II module is configured in Default mode or Transparent mode

Strany 22

26 Transparent Mode Setup This parameter makes it possible to use all untagged data as the management domain by entering N, or to define a VLAN ID ta

Strany 23

iii Table of Contents FCC Radio Frequency Interference Statement ------------------------------------------------- ii Warranty -----------------------

Strany 24 - Command Description

27 Transparent with VLAN Tag on EXT MGMT Port This parameter adds the management VLAN ID tag to all untagged data arriving at the EXT MGMT port by en

Strany 25

28 Default Mode Entering N in the Tags column of both the Optics and Data rows will place the iMcV-Giga-FiberLinX-II in Default mode. No VLANs are

Strany 26

29 Port VLAN on DATA Port This parameter restricts traffic to a single VLAN ID tag for the DATA port by entering Y in the Tags column of the Data row

Strany 27

30 Port VLAN Filter This parameter allows passing traffic with up to 32 separate VLAN IDs between the OPTICS (or UPLINK) port and the DATA port. To

Strany 28

31 Unit FiberAlert – Enables/disables FiberAlert and LinkLoss functionality on the unit. The settings include: • No FiberAlert Or LinkLoss Enabled •

Strany 29 - ***WARNING***

32 Bandwidth Configuration—bw The iMcV-Giga-FiberLinX-II allows viewing bandwidth status and configuring bandwidth from a serial connection or a Teln

Strany 30

33 • How will the iMcV-Giga-FiberLinX-II units be managed? • Will VLAN IDs be defined? How many iMcV-Giga-FiberLinX-II units will be used? • Two for

Strany 31

34 Mode One-Default Default mode passes only untagged data between the DATA port and the OPTICS (or UPLINK) port. This mode is the factory default

Strany 32

35 c. Press S or F3 to save without setting any transparent mode options. This will set all untagged traffic as management. d. Type Reboot. In thi

Strany 33

36 NOTE The flow of management domain traffic is defined by the DIP Switches. For example, if the management DIP Switches are on the OPTICS and DAT

Strany 34

1 About the iMcV-Giga-FiberLinX-II NOTE Unless noted otherwise, all references to the iMcV-Giga-FiberLinX-II in this manual are also applicable to th

Strany 35

37 Mode Three-Transparency with Tagged Management Transparent with Tagged Management mode passes both tagged and untagged traffic between the DATA po

Strany 36

38 e. Ensure Are VLAN Tags required on the EXT Port? is set to N. f. Press S or F3 to save the settings. This will set all traffic with VLAN ID 7 as

Strany 37

39 data received on the Remote iMcV-Giga-FiberLinX-II DATA port can be extra-tagged and sent out of the Host iMcV-Giga-FiberLinX-II DATA port with a

Strany 38

40 The Data Tag is [8 ] Data Priority is [0 ] Are Extra Tags left on the Data Port? [ N ] Select the TPID for

Strany 39

41 Mode Five-Port VLAN The Port VLAN mode allows configuring the iMcV-Giga-FiberLinX-II to accept only data tagged with one specific VLAN ID. This m

Strany 40

42 Enter a VLAN ID in the Management VLAN IDs field. VLAN IDs Priorities Tags Current Saved Current Saved Ports

Strany 41 - Settings

43 VLAN on OPTIC Port - Configuration To configure this mode, do the following: 1. In the Main Configuration screen, press the Space Bar and type con

Strany 42

44 4. Enter a VLAN ID in the Management VLAN IDs field. VLAN IDs Priorities Tags Current Saved Current Saved Po

Strany 43

45 Mode Six-Port VLAN Filter The VLAN filter mode allows isolating a segment of the network to only accept data using some or all of the 32 available

Strany 44

46 4. Enter a VLAN ID in the Management VLAN IDs field. Enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to 4094. Data VLA

Strany 45 - Giga-FiberLinX-II

2 The iMcV-Giga-FiberLinX-II module is a double-slot, chassis-mounted module. Compatible chassis include the following: • iMediaChassis series • Med

Strany 46

47 Troubleshooting • If two iMcV-Giga-FiberLinX-II Host/Remote units are not communicating properly, make sure one is a Host and the other is a Remot

Strany 47

48 • To restore the unit to factory default settings, use the cleandb function via the serial port (refer to the Device-Specific Options from the Com

Strany 48

49 Serial Port Pinout The following table lists the pin configuration for the RJ-45/Serial connector. The serial port shares the physical connector

Strany 49

50 Modes of Operation Modes of OperationsYESNOTransparentModeTAG Requiredon MGMTPacketTAG Required (Exists) on EXT MGMT PortYes / No to add TAGAdd E

Strany 50

51 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Strany 51

52 Specifications Power Consumption (Typical): 850mA @ 3.6V DC Max. Operating Temperature: +32°F to +122°F (0°C to +50°C) Storage Temperature: -13°F

Strany 52 - Pin Signal

53 Standards/Compliance • Read/write IEEE 802.1Q VLAN tags • QoS IEEE 802.1p-based packet prioritization (2 queues [high/low] with 8 levels of priori

Strany 53 - Modes of Operations

54 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, wh

Strany 54

55 Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units containing

Strany 55

56 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produ

Strany 56

3 take effect. Refer to About Serial Port Configuration for more information about Enabling/Disabling DHCP. When there is no DHCP server on the netwo

Strany 57

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2010 IMC N

Strany 58

4 iView2 Management Software iView² is the IMC Networks management software designed specifically for the IMC Networks iMcV family of modules. It fe

Strany 59

5 Installation Each iMcV-Giga-FiberLinX-II module requires two slots in an iMediaChassis, MediaChassis or IE-MediaChassis. To install the module in

Strany 60

6 LED Operation iMcV-Giga-FiberLinX-II features diagnostic LEDs as shown below. TX/FX LEDs FDX/COL: • Glows yellow when port is operating in Full-Du

Komentáře k této Příručce