iMcV-Giga-FiberLinX-II Operation Manual
6 III - Hardware Configuration Before installing the module in a chassis, there are two features that must be selected using the DIP switches. These
7 queried by SNMP. As a Remote unit, the iMcV-Giga-FiberLinX-II will respond to requests for management information from an attached Host unit. The
8 IV - Installation Instructions Each iMcV-Giga-FiberLinX-II module requires two slots in an iMediaChassis or MediaChassis. To install the module i
9 Assigning IP Information When the iMcV-Giga-FiberLinX-II is installed in an iMediaChassis, you can use UMA to manage your iMcV-Giga-FiberLinX-II wi
10 Advertising, rather than Force Mode, when connecting to devices that only use autonegotiation. Refer to Port Configuration on page 19 for more in
11 FiberAlert FiberAlert minimizes the problems associated with the loss of one strand of fiber. Normally when a single strand of fiber is lost, the
12 Loopback Testing on Remote or Standalone The following functions are available during loopback testing. During loopback testing, management traff
13 VI - Using Telnet You must assign the iMcV-Giga-FiberLinX-II an IP address before using a Telnet session (this is not necessary when you are using
14 Basic Device Configuration After running through an initial self test, the prompt: “Press <Enter> for Device Configuration” displays. Press
15 NOTE After making any modifications to the Saved Values, reboot the unit for your changes to take effect. To reboot, type the word reboot at the
FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant
16 (T) - Assigning SNMP Trap Destinations Traps are sent by the manageable device to a management PC when a certain event takes place. To enter a t
17 (U) - Deleting All SNMP Community Strings To delete all community strings and start over, press U. You will then be prompted, “Are you sure you
18 Command Description See Page ifstats Displays interface statistics. rmstats Displays RMON statistics. version Displays the firmware and hardw
19 7. The download progress displays and ends with a successful download message or with an error message. 8. Press Q or F4 to return to the Device-S
20 Advertise Ctrl–Selective advertising is used in combination with autonegotiation to advertise your selected speed and duplex mode for the DATA and
21 NOTE Default mode is the factory default and is provided as a starting point from which to configure the iMcV-Giga-FiberLinX-II modules. This mod
22 Transparent Mode Setup This parameter allows you to use all untagged data as the management domain by entering N, or allows you to define a VLAN I
23 VLAN Mode Screen When you enter N in the Transparent Mode Setup screen (page 22), the VLAN Mode screen displays: In this screen you can set the
24 No VLANs are defined allowing only untagged packets to pass through the unit. Port VLAN on OPTICS (or UPLINK) port This parameter allows you to r
25 must enter Y in the Tags column for both the Optics row and Data row. Enter up to 32 VLAN IDs in the Data VLANs fields, plus one for SNMP. Manag
Table of Contents FCC Radio Frequency Interference Statement ------------------------------------------------ ii Warranty-----------------------------
26 Configuration screen, press the space bar, type unit, and press Enter to open the Unit Control Settings screen. In this screen you can view the u
27 Unit Max FrameSz–enter the maximum frame size on the unit by using the number keys. The valid values are 1518 to 12196. 802.1p Base Pri–set the t
28 NOTE It is not recommended to set both the RX and TX Bandwidth limits at the same time. Unit RateControl Enable/Disable–enable or disable the ban
29 Will you define VLAN IDs? When you want to use VLAN traffic with specific tags on any/all of the DATA ports, you will need to disable Transparency
30 Transparent with Untagged Management Transparent with Untagged Management mode passes tagged traffic between the DATA port and the OPTICS (or UPLI
31 NOTE The flow of management domain traffic is defined by the DIP switches. For example, if the management DIP switches are on the OPTICS and DATA
32 Transparent with Tagged Management Transparent with Tagged Management mode passes both tagged and untagged traffic between the DATA port and the O
33 d. Enter the management tag (VLAN ID) and the priority (optional). Is a VLAN tag required on Management packets? [ Y ] The Management Tag i
34 Transparent with Extra Tagging (Q-in-Q) Transparent with Extra Tagging mode can add an extra tag to data received on the DATA port. By using Extr
35 Enter the extra tag VLAN ID (for example, 8) and the Priority (optional). These values must be identical on both iMcV-Giga-FiberLinX-II modules.
iv Transparent with Extra Tagging (Q-in-Q)-------------------------------------------------- 34 Port VLAN---------------------------------------------
36 Port VLAN The Port VLAN mode allows you to configure the iMcV-Giga-FiberLinX-II to accept only data tagged with one specific VLAN ID. This mode c
37 In the SNMP field, type Y. VLAN IDs Priorities Tags Current Saved Current Saved Ports
38 VLAN on OPTIC Port–Configuration To configure this mode, do the following: 1. In the Main Configuration screen, press the space bar and type confi
39 5. Press S or F3 to save the settings. 6. Type reboot. The iMcV-Giga-FiberLinX-II is now configured to pass only VLAN ID 13 from the OPTICS (or UP
40 Port VLAN Filter The VLAN filter mode allows you to isolate a segment of the network to only accept data using some or all of the 32 available VLA
41 Enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to 4094. Only the VLANs in this list will pass through the unit. Data
42 Now the iMcV-Giga-FiberLinX-II is configured to pass only packets with tags containing the VLAN IDs defined in the Data VLANs table. VLAN ID numb
43 IX - Troubleshooting • If two iMcV-Giga-FiberLinX-II Host/Remote units are not communicating properly, make sure one is a Host (DIP switch #8) and
44 • To restore the unit to factory default settings, use the cleandb function via the serial port (refer to the Device-Specific Options from the Com
45 Troubleshooting LinkLoss/FiberAlert/Link Fault Pass-Through The following diagrams show you how the different troubleshooting configurations for t
1 I - About the iMcV-Giga-FiberLinX-II Overview The iMcV-Giga-FiberLinX-II™ allows network operators to deploy managed Ethernet services, with a full
46 FX LinkLoss Normally when a fault occurs on the fiber segment of an iMcV-Giga-FiberLinX-II conversion, only the fiber port LEDs on the modul
47 TX LinkLoss When a fault occurs on a twisted pair segment joining a device to an iMcV-Giga-FiberLinX-II module, the link fault is not detected by
48 FiberAlert ***WARNING*** Do not enable FiberAlert at both ends. This can cause the fiber link to lock up. When FiberAlert is enabled on
49 Link Fault Pass-Through
50 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020
51 Serial Port Pinout The iMcV-Giga-FiberLinX-II features a serial port that uses an IBM-compatible DB-9 serial connector. To connect an iMcV-Giga-F
52 Notes
53 Notes
54 Notes
55 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produ
2 The iMcV-Giga-FiberLinX-II module is a double-slot, chassis-mounted module. Compatible chassis include the following: • iMediaChassis series • Med
19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2007 IMC Networks. All ri
3 2iView Management Software iView² is the IMC Networks management software designed specifically for the IMC Networks “iMcV” family of modules. It
4 About Dynamic Host Control Protocol (DHCP) The iMcV-Giga-FiberLinX-II module includes a Dynamic Host Control Protocol d use that (DHCP) client. B
5 II - LED Operation The following are iMcV-Giga-FiberLinX-II diagnostic LEDs. In this example, the functions for a 1x9 fiber port version (SC fiber
Komentáře k této Příručce