IMC Networks IE-IMCV Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Převaděče síťových médií IMC Networks IE-IMCV. IMC Networks IE-IMCV User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 60
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
IE-iMcV-MultiWay
Operation Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - Operation Manual

IE-iMcV-MultiWay Operation Manual

Strany 2 - Warranty

6 DIP Switch configuration DIP Switch Name Description Default Setting 1 Dual Enable dual channel OFF 2 1+1 Provides 1+1 protection with

Strany 3

7 LED Operation Each IE-iMcV-MultiWay includes SFP and RJ-45 LEDs. (TX 1, TX 2) LNK/ACT FDX SFP A, SFP B OAM ACTIVE LNK FLT Glows

Strany 4

8 Configuration The IE-iMcV-MultiWay includes many features that are configurable via a serial/Telnet session (CLI) or through iView² (SNMP Managemen

Strany 5

9 Basic Device Configuration Using the CLI After running through an initial self test, the screen will display the following message: Press Enter for

Strany 6

10 This screen contains the following information and options: Saved and Current Values Saved values display the changes made during the current ses

Strany 7

11 sensitive and must not exceed eight characters or include spaces, and press Enter. This password will be requested whenever logging on. To remov

Strany 8

12 Deleting Community Strings To delete all community strings, perform the following: Press U. The "Are you sure you want to delete all future

Strany 9

13 DHCP Disable (Static IP Addressing) DHCP is disabled in the default configuration. Initially, modules are assigned a Static default IP Address of

Strany 10

14 Commands List (Space Bar) The IE-iMcV-MultiWay also includes several device-specific options. To access these options, press the Space Bar from

Strany 11

15 Command Description unit Unit global settings, frame size selection. Unit OAM enable must be enabled for AH and AG to function. port Displays

Strany 12

ii FCC Radio Frequency Interference Statement Class A (using 48V Telco type power) This equipment has been tested and found to comply with the limits

Strany 13

16 After the transfer process is complete, press Enter to load the configuration file: Once loaded into the device's SNMP memory area, the syst

Strany 14

17 Viewing Port Statistics To view port statistics on the IE-iMcV-MultiWay, enter ifstats. This will open a screen displaying information on packets

Strany 15

18 Version Entering version will display the version of the firmware operating the IE-iMcV-MultiWay. Settings should be saved prior to reboot. Reboot

Strany 16

19 Port Configuration Serial/Telnet sessions display port status as well as allowing configuration of some port features. Type port and press Enter t

Strany 17

20 Advertise FlowC and Force FlowCtrl - This is the FlowControl feature. • When using FlowControl functionality on any port, enable Global FlowContro

Strany 18

21 Operational Mode Configuration There are two modes of operation that can be configured through the Serial/Telnet session: Mode 1, which supports a

Strany 19 - Command Description

22 Operation Mode 2 Port Based Xtra Tagging Any port can be configured for extra tags on the frames. Press the down arrow on the computer keyboard t

Strany 20

23 VLAN Configuration The ports can be assigned as a trunk or access port. When configuring a trunk port, an Ethertype can be user-defined (a trun

Strany 21

24 OAM AH (Operation and Administration Management) Two modes of operations control the OAM function, Passive and Active. Passive mode is the defau

Strany 22

25 Using iView2 iView² is IMC Networks’ management software, providing network management in an easy to use Graphical User Interface (GUI). Once iV

Strany 23

iii Table of Contents FCC Radio Frequency Interference Statement ... ii Warranty...

Strany 24

26 The following functions can be performed via iView2: Function Description Unit Configuration Display/modify unit information. Port Configuration

Strany 25

27 Port Configuration Select Port Configuration to display/modify port information including description and flow control:

Strany 26

28 Tables Select tables to display a screen from which to select the specific statistics to be viewed: Select Unit and Port Tables to display the fo

Strany 27

29 Enter a VLAN ID between 1 and 4,094; possible priority settings are 0 (lowest priority) through 7 (highest priority). Advanced Select Advanced to

Strany 28

30 OAM AH Select OAM AH to display the following screen and monitor the status, configuration, loopback, event log and statistics:

Strany 29

31 From the above screen, select Configuration to display state and event configuration information as well as OAM supported functions: Select Loopb

Strany 30

32 Select Event Log to display the OAM event log showing changes that have occurred via OAM configuration: Select Statistics to display OAM statisti

Strany 31

33 OAM CFM Select OAM CFM to display the following screen and perform administrative control for Maintenance Domains (MDs), Maintenance Assocations (

Strany 32

34 For the first-time configuration, the user must first create an MD, then an MA, then local and peer MEPs can be added. To create an MD, select th

Strany 33 - 7 (highest priority)

35 For the first configuration, create an MA after the MD. Select "Configure MA" to display the OAM CFM Maintenance Association Configurat

Strany 34

iv RS-232 Serial Console Port...45 Product Applications ...

Strany 35

36 Select the MD, MA, enter the MEP ID, select the appropriate type, port and direction, and select the Primary VID, if applicable. To cancel the ME

Strany 36

37 The MEP Instance Configuration page offers more details about an individual MEP as shown below: From this screen, the user can perform the follow

Strany 37

38 Agent Info Select Agent Info to display SNMP agent data:

Strany 38

39 Connecting the IE-iMcV-MultiWay to an iMcV-Giga-FiberLinX-II If the IE-iMcV-MultiWay is being set up as a Remote (CPE) to a Host connection with a

Strany 39

40 Configuration File Save/Restore Function Requirements The Configuration File Save/Restore Function allows a user the ability to backup all the con

Strany 40 - Color Description

41 Saving a Configuration File to Disk: From the Administration Tab in iView2 (iConfig view) click the Save Configuration button: The user is prom

Strany 41

42 The user is prompted to enter any notes to the header of the saved file for future reference when uploading the file through iView2 (iConfig view)

Strany 42

43 Uploading a Saved Configuration File through iView2 (iConfig view) From the Administration Tab in iView2 (iConfig view) click the Upload Configura

Strany 43

44 SFP Ports The IE-iMcV-MultiWay SFP ports support gigabit fiber SFPs and 100Mbps fiber SFPs, with or without Digital Diagnostics Monitoring Inform

Strany 44

45 RJ-45 Data Port Pinout The following table lists the pin configuration for the RJ-45 Data connector. Pin Signal Name 1000M Signal Direction 10/

Strany 45

1 About the IE-iMcV-MultiWay The IE-iMcV-MultiWay is a CPE device, available as a modular device providing two fixed 10/100/1000Base-T copper ports

Strany 46

46 Product Applications For a detailed description of the product applications, please refer to the IE-iMcV-MultiWay data sheet at http://www.imcnetw

Strany 47

47 Glossary The following are terms and phrases used within this manual, or which are found in documents associated with this equipment. Term/Acronym

Strany 48

48 Term/Acronym Definition MDI/MDIX Media-Dependent Interface/ Media-Dependent Interface Crossover. The ability of an Ethernet port to automatically

Strany 49

49 Troubleshooting If a fiber connection cannot be established, perform the following to make sure that the fiber transceivers on the IE-iMcV-MultiWa

Strany 50

50 Specifications Ethernet Connections • SFP 1000 Base-X • SFP 100 Base –FX • SFP 10/100/1000 Copper (SGMII) • 10/100/1000 BaseT (Fixed Copper ports)

Strany 51

51 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Strany 52

52 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, wh

Strany 53

53 Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing

Strany 54

54 Notes

Strany 55

55 Certifications CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC). Europea

Strany 56

2 About IE-iMcV-MultiWay Features and Configuration The IE-iMcV-MultiWay offers a full feature set including Auto Negotiation, Selective Advertising,

Strany 57

19772 Pauling y Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 y FAX: (949) 465-3020 www.imcnetworks.com © 2011 IMC Networks. All

Strany 58

3 When using iView2, the IE-iMcV-MultiWay can be fully managed without an IP address using a secure management channel. However, an IP address can b

Strany 59

4 About iView2 (iConfig view) iView2 (iConfig view) is an in-band utility created by IMC Networks, used for SNMP configuration for IMC Networks’ SNM

Strany 60

5 DIP Switch Selectable Mode Configuration The IE-iMcV-MultiWay can be configured in one of the following ways via DIP Switch settings (see page 6):

Komentáře k této Příručce